Vitek 2 compact 60 pdf

All identification stages from reading to the recording of results are automated, optimizing workflow. The efficiency of the vitek 2 compact system relies on the advanced colorimetry technology. Capable of performing gramnegative, grampositive and yeast identification and susceptibility tests. The instrument monitors the growth of each well in the card over a defined period of time up to 18 hours for bacteria or up to 36 hours for yeast. Vitek 2 compact identifies the vast majority of microorganisms that contaminate production areas and finished products in a minimum amount of time. None of the equipment posted for sale on is owned by medwow, should you have any questions regarding a specific item, please direct them to the appropriate seller by making use of the available communication channels on the items page. All three systems accommodate the same colorimetric reagent cards that are incubated and. Manufacturer specifications vitek 2 compact, biomerieux please note. Used biomerieux, vitek 2, microbiological culture analyzer.

Place filling stand with the assembled test kit into filling module. Vitek 2 technology represents a smarter way to automate idast testing. The system reads the latest generation vitek test cards containing 64 wells to ensure accuracy every 15 minutes using three different wavelengths. The 2 xl microbiology analyzer is a microbial identification. The first vitek systems were developed through a collaboration between mcdonnel douglas and. Microbial identification using vitek 2 pdf pdadhi parenteral. The vitek 2 is an automated microbiology system utilizing growthbased technology. The configuration that you have purchased is adapted to the legislation. Us environmental protection agency office of pesticide. Scan the vitek id card barcode and insert the blue tube portion hockey stick of the vitek card into the inoculum.

Dec 09, 20 this feature is not available right now. Vitek 2 compact 30 place instrument, in service date may 2006 windowsbased operating system without os disks. Vitek 2 uses unique id and ast cards the size and shape of a playing card. A preinserted transfer straw means less manual steps. Modifications by biomerieux can be made without prior notice biomerieux, the blue logo, advanced expert system, bioart, densichek, myla, vilink and vitek are used, pending andor registered trademarks belonging to biomerieux, or one of its subsid iaries, or one of its. Scan cassette worksheet at the work station vitek 2 is designed to make your idast workflow as rapid and reliable as possible, while providing maximum flexibility and full traceability. Vitek 2 instrument user manual i 51073110en1 general warnings important.

Biomerieux inc 595 anglum rd hazelwood mo 630422320. Agreement and cost comparison of vitek2 compact, vitek2 60, vitek ms systems and api20ene using clinical gramnegative bacilli isolates from jamaica conference paper pdf available september. Nasa to help astronauts identify microorganisms in space. Use the arrow key to move to the next cassette position. Any unsaved data will not be recovered when the inactivity time limit set at 60 minutes has been exceeded. This study highlights the level of microbial contamination of waterpipe components in selected area of saudi arabia and the resistance of selected bacteria to different antibiotics was determined. Isolates were analyzed by the vitek2 compact c at the uwi laboratory then shipped to canada for identification by other methods that included vitek 2 60, api20e or api20ne and by malditof using. Vitek 2 were prepared in sterile saline to a turbidity equal to a 2. Gain the expert confidence of rapid, accurate idast testing through full automation. Give special consideration to specimen source and patient drug or antimicrobic regimen. Choose isolate prepare organism suspension and ensure correct mcfarland standard with densichek plus vitek 2 compact. The 2 xl microbiology analyzer is a microbial identification system for fast and accurate testing.

Thermo scientific vitek 2 qc sets include a readytouse set of qc organisms in cultiloops for. Use of the vitek 2 system for rapid identification of. Comparison of bd phoenix to vitek 2, microscan microstrep. Pdf agreement and cost comparison of vitek2 compact. Analysis of samples by vitek 2 revealed that staphylococcus aureus 40% was the most common bacterial isolate followed by enterococcus. Pdf agreement and cost comparison of vitek2 compact, vitek2. Verification and validation in clinical microbiology. The vitek 2 compact bacterial identification system, which is available in three sizes, brings vitek 2 technology to laboratories of every size. Used microbiological culture analyzer biomerieux vitek 2. The refurbished biomerieux vitek 2 compact idast system has everything laboratories need for fast, accurate microbial identification and susceptibility testing. The use of vitek 2 compact for microbial identification has been reported and endorsed by several authors quesada et al. Vitek 2 xl vitek 2 compact vitek 2 0118 93192002gbe document andor pictures not legally binding. This improvement will be included in the software release version 4. The carousel, shown in figure 48, has a capacity of 60 test cards.

Ergonomic analysis comparison of the vitek 2 and vitek 2 compact. The system is available in three formats vitek 2 compact, vitek 2, and vitek 2 xl that differ in increasing levels of capacity and automation. Use id suspension to make ast suspension vitek 2 compact. Vitek 2 compact identification cards gp, bcl, and gn. Identification and antibiogram of various gram positive. If either the vitek 2 instrument or the smart carrier. Too little decolorization can result in a false positive result.

Usefulness of chromagar candida medium, biochemical methods. We can even customize your database to track facilityspecific organisms. Each standardized inoculum suspension was placed into a vitek 2 cassette along with a sterile polystyrene test tube and a yeast susceptibility test card. Application product type product name product description product number. Used biomerieux vitek 2 compact microbiology for sale. As the system operates with barcoded cards, full traceability is ensured and the risk of transcription errors is minimized. Press f1 to copy the order and isolate numbers from the previous. Focus on a new generation of test cards our unique vitek test card has been redesigned for vitek 2 compact. Compact 1x2 hdsdi reclocking video distribution amplifier. Reanalysis of data with the new software has shown a dramatic improvement in identification rates from all media types used. Densichek plus meter with mcfarland standards for calibration 0.

Increase work capacity by connecting 2 readerincubator modules together. Densichek meter with mcfarland standards for calibration see section 15. Vitek 2 compact vtc, vitek 2 60 vt60 and api20ene all biomerieux use biochemicals for bacterial identification id, while the vitek ms. Us environmental protection agency office of pesticide programs. Vitek 2 compact identification cards for example, gp, anc, bcl, and gn. Bcl cards were filled automatically in the vitek vacuum chamber, sealed, incubated at 355c and read automatically every 15 min for 14 h. Building construction, power outages and equipment maintenance may cause transient aberrant counts. Use of the vitek 2 system to identify and test the antifungal. Microbiological identification and antibiotic susceptibility testing system. Vitek 2 compact 60 configuration vitek 2 pc configuration.

Available in two sizes, the refurbished biomerieux vitek 2 compact is easy to set up and operate and it features advanced colorimetry identification technology to enhance performance. Biomerieux vitek 2 compact microbiological culture. Quality control for quality control purposes, the required information is documented on the appropriate forms see section 14. Laboratory personnel need to be aware of the current limitations with this gn card and the software version 4. Vitek 2 compact, automated idast instrument biomerieux. The ast pattern of the isolates was also obtained by vitek 2 compact automated system. Jun 06, 2017 identificacao bacteriana automatizada. Uniden bc346xt handheld trunktracker iii analog police scanner manual, the vitek 2 the rapid response time means results can be provided more quickly than with manual the vitek 2 compact.

Vaillant ecotec 624, vitek 2 compact instrument user manual. Based on conventional method and idyst card system vitek 2, candida albicans was predominant 60 116 51. With this technique, more data is analyzed, which increases results and accuracy. Ensure highperformance products, reproducible clinical test results and consistent microbiological evaluation of pharmaceuticals and food with thermo scientific cultiloops quality control organisms.

Place assembled card and transfer tube on filling stand with the long portion of the transfer tube into the test tube. For larger volume labs, vitek 2 is available in two sizes. Vitek 2 compact instrument dimensions mass height 60 cm 23. Evaluation of the vitek2 bcl card for identification of.

Use of various common isolation media to evaluate the new. Application using colorimetric reagent cards, the vitek 2 incubates and processes samples to identify. Used biomerieux vitek2 compact microbiology analyzer for. Vitek manual table of contents mount sinai hospital. Vitek 2 compact brochure antibiotics antimicrobial. Sixtyfour well iuo cards were then loaded into the. The cassettes were placed in the vitek 2 instrument. Xl systems are designed for large microbiology laboratories requiring high test throughput. The results obtained with vitek 2 yst card were correct with api identification for the majority of common clinical yeasts, c. Vitek 2 compact is designed for medium to smallsized laboratories which require an automated system. Interpretation of test results requires the judgment and skill of a person knowledgeable in microbial identification testing. New vitek 2 colorimetric gn card for identification of gram. The user is advised to read and understand all instructions in this manual to be able to derive the best performance from the vitek 2 instrument and the smart carrier station.

627 603 817 665 173 1520 1225 1171 165 766 1169 1455 164 427 1037 368 709 118 1256 1106 99 783 1079 945 83 315 1260 254 356